Experimental Study of the Effect of the Reynolds Number on Overall Heat Transfer Coefficient in Spiral Heat Exchanger for Acetic Acid – Water System

International Journal of Chemical Engineering Research
© 2018 by SSRG - IJCER Journal
Volume 5 Issue 2
Year of Publication : 2018
Authors : R.W.Tapre, Dr.J.P.Kaware
pdf
How to Cite?

R.W.Tapre, Dr.J.P.Kaware, "Experimental Study of the Effect of the Reynolds Number on Overall Heat Transfer Coefficient in Spiral Heat Exchanger for Acetic Acid – Water System," SSRG International Journal of Chemical Engineering Research, vol. 5,  no. 2, pp. 1-5, 2018. Crossref, https://doi.org/10.14445/23945370/IJCER-V5I2P101

Abstract:

In this paper an experiments has been conducted to investigate overall heat transfer coefficient for co-current and counter current flow in spiral heat exchanger. Cold fluid is acetic acid water miscible solution. A series of runs were performed between hot and cold fluid. Hot fluid flows through spiral tube while cold fluid flows through shell side. Mass fraction of cold fluid was varied from 5 to 30%.For each run hot fluid flow rate was kept constant and the mass flow rate of cold fluid was varied from 5 lpm to 8 lpm. Experiments were performed to study the effect of Reynolds number on overall heat transfer coefficient.

Keywords:

Spiral heat exchanger, Reynolds Number, Overall Heat Transfer Coefficient

References:

[1] Prakash J Sakariya, Prof. Priyanka M Jhavar, Prof.Ravi D Gujarati, “Review Paper on Analysis of Heat Transfer in Spiral Plate Heat Exchanger Using Experimental and CFD,” IJSRD - International Journal for Scientific Research & Development| Vol. 2, Issue 06, 2014
[2] S.Sathiyan, M. Rangarajan, S. Ramachandran “An experimental study of spiral-plate heat exchanger for nitrobenzene-water two-phase system,” Bulgarian Chemical Communications, Volume 42, Number 3 (pp. 205–209) 2010.
[3] Esam Jassim, “Spiral Coil Heat Exchanger- Experimental Study,” Proceedings of the 3rd International Conference on Fluid Flow, Heat and Mass Transfer (FFHMT’16) Ottawa, Canada – May 2 – 3, 2016.
[4] Delia Garleanu, Gabriel Garleanu, Claudia Borda, Delicia Arsene, “The new repair technology the spiral heat exchangers” International Journal of Scientific & Engineering Research, Volume 7, Issue 10, October-2016.
[5] M.R.Haque, “Minimizing fouling in spiral heat exchangers at a BCTMP mill,” Pulp & Paper Canada, 108:4, pp. 35-44, (2007).
[6] M.Bidabadi, A.K. Sadaghiani and A. Vahdat Azad, “Spiral heat exchanger optimization using genetic Algorithm,” Scientia Iranica B 20(5), 1445-1454, (2013).
[7] Santosh D Katkade, Prof J H Bhangale , Prof D D Palande, “Experimental Investigation of Spiral Fin Tube Heat Exchanger with Different Fin Thickness” International Journal of Research in Advent Technology, Vol.3, No.1, January 2015.
[8] Roshan. V. Marode, Ashok. J. Keche, “Thermal Analysis Validation for Different Design Tubes in a Heat Exchanger,” International Conference of Advance Research and Innovation (ICARI-2015).
[9] R.W.Tapre, Dr. J. P. Kaware, “ Heat Transfer Characteristic of Spiral Heat Exchanger: Effect of Reynolds Number on Heat Transfer Coefficient for Acetic Acid - Water System,” International Journal of Scientific Research in Science and Technology, Volume 4, Issue 8,2018.
[10] R.W.Tapre, Dr. J. P. Kaware, “Experimental Analysis of Spiral Heat Exchanger: Evaluation of Reynolds Number and Nusselt Number for Acetic Acid – Water System,” International Journal of Scientific Research in Science and Technology, Volume 4, Issue 9, 2018.