Call For Paper November 2026

Research Article | Open Access | Download PDF
Volume 13 | Issue 11 | Year 2026 | Article Id. IJME-V13I11P103 | DOI : https://doi.org/10.14445/23488360/IJME-V13I11P103

Performance Evaluation of Pulsed Eddy Current Testing for Detection and Thickness Estimation of Corrosion under Insulation in Carbon Steel Pipeline Structures


Yuli Panca Asmara, Juro Dufan Saragih, Kesavan, Sophian Ali Rahman, Rahman, Firda Herlina

Received Revised Accepted Published
10 Mar 2026 30 Apr 2026 25 Nov 2026 27 Nov 2026

Citation :

Yuli Panca Asmara, Juro Dufan Saragih, Kesavan, Sophian Ali Rahman, Rahman, Firda Herlina, "Performance Evaluation of Pulsed Eddy Current Testing for Detection and Thickness Estimation of Corrosion under Insulation in Carbon Steel Pipeline Structures," International Journal of Mechanical Engineering, vol. 13, no. 11, pp. 25-33, 2026. Crossref, https://doi.org/10.14445/23488360/IJME-V13I11P103

Abstract

Corrosion under Insulation (CUI) is one of the major degradation problems in insulated pipeline systems because it may occur beneath the insulation layer and remain undetected during routine visual inspection. Conventional inspection often requires partial or complete removal of insulation, which increases sinspection time, cost, and operational interruption. This study evaluates the capability of Pulsed Eddy Current (PEC) testing as a non-destructive technique for detecting thickness variation associated with CUI in carbon steel pipeline structures. Carbon steel specimens with different thicknesses were examined under several insulation conditions, including acrylic, rubber, and wood insulation with thicknesses of 1, 3, and 5 mm. The PEC signal slope was used as the main feature for estimating carbon steel thickness, and the estimated values were compared with actual thickness measurements to determine the percentage error. The results show that PEC signals are affected by carbon steel thickness, insulation material, and insulation thickness. Increasing carbon steel thickness generally reduced the PEC signal response, while insulation material and insulation thickness modified the signal amplitude and slope. The lowest measurement errors were obtained under non-insulated conditions, while higher errors were observed when insulation was applied. These findings indicate that PEC testing has potential for CUI-related thickness estimation without removing insulation; however, signal calibration, insulation effects, and environmental parameters must be carefully considered to improve reliability for field applications. This study also supports SDG 9: Industry, Innovation and Infrastructure by promoting industrial and innovation in non-destructive inspection technologies and improving the reliability and integrity of industrial pipeline infrastructure.

Keywords

Carbon steel, Corrosion under Insulation (CUI), Insulation materials, Non-Destructive Testing (NDT), Pulsed Eddy Current (PEC).

References

  1. P. Roffey, and E.H. Davies, “The Generation of Corrosion under Insulation and Stress Corrosion Cracking due to Sulphide Stress Cracking in an Austenitic Stainless Steel Hydrocarbon Gas Pipeline,” Engineering Failure Analysis, vol. 44, pp. 148-157, 2014.
    [
    CrossRef] [Google Scholar] [Publisher Link]
  2. Khan Muhammad Mohsin, Ainul Akmar Mokhtar, and Peter W. Tse, “A Fuzzy Logic Method: Predicting Corrosion under Insulation of Piping Systems with Modelling of CUI 3D Surfaces,” International Journal of Pressure Vessels and Piping, vol. 175, pp. 1-14, 2019.
    [
    CrossRef] [Google Scholar] [Publisher Link]
  3. Yuan-Hao Tsai et al., “A BIM-based Approach for Predicting Corrosion under Insulation,” Automation in Construction, vol. 107, pp. 1-14, 2019.
    [
    CrossRef] [Google Scholar] [Publisher Link]
  4. TWI Ltd., What is Non-Destructive Testing (NDT)? Methods and Definition, TWI Ltd., 2026. [Online]. Available: https://www.twi-global.com/technical-knowledge/faqs/what-is-non-destructive-testing
  5. Gino De Landtsheer, Corrosion under Insulation (CUI) Guidelines: Technical Guide for Managing CUI, 3rd ed., Woodhead Publishing, vol. 55, 2020.
    [
    Google Scholar] [Publisher Link]
  6. Neil Wilds, Corrosion under Insulation, Trends in Oil and Gas Corrosion Research and Technologies, Woodhead Publishing, pp. 409-429, 2017.
    [
    CrossRef] [Google Scholar] [Publisher Link]
  7. Qing Cao et al., “A Review of Corrosion under Insulation: A Critical Issue in the Oil and Gas Industry,” Metals, vol. 12, no. 4, pp. 1-24, 2022.
    [
    CrossRef] [Google Scholar] [Publisher Link]
  8. Ali Sophian, Guiyun Tian, and Mengbao Fan, “Pulsed Eddy Current Non-Destructive Testing and Evaluation: A Review,” Chinese Journal of Mechanical Engineering, vol. 30, no. 3, pp. 500-514, 2017.
    [
    CrossRef] [Google Scholar] [Publisher Link]
  9. C.S. Angani et al., “The Pulsed Eddy Current Differential Probe to Detect a Thickness Variation in an Insulated Stainless Steel,” Journal of Nondestructive Evaluation, vol. 29, no. 4, pp. 248-252, 2010.
    [
    CrossRef] [Google Scholar] [Publisher Link]
  10. Eddyfi Technologies, Corrosion under Insulation: The 7 Inspection Methods you Must Know About, Eddyfi Technologies, 2026. [Online]. Available: https://blog.eddyfi.com/en/corrosion-under-insulation-the-7-inspection-methods-you-must-know-about
  11. American Petroleum Institute, API Recommended Practice 583: Corrosion under Insulation and Fireproofing, 2nd ed., American Petroleum Institute, 2024. [Online]. Available: https://www.api.org/-/media/files/publications/2025-catalog/06_refining_2025.pdf
  12. ASTM International, “Standard Specification for Thermal Insulation for use in Contact with Austenitic Stainless Steel,” ASTM International, 2023.
    [
    CrossRef] [Publisher Link]
  13. Q. Cao et al., “Corrosion of Mild Steel under Insulation-The Effect of Dissolved Metal Ions,” Corrosion Engineering, Science and Technology: The International Journal of Corrosion Processes and Corrosion Control, vol. 55, no. 4, pp. 322-330, 2020.
    [
    CrossRef] [Google Scholar] [Publisher Link]
  14. ASTM International, “Standard Guide for Laboratory Simulation of Corrosion under Insulation,” ASTM International, 2021.
    [
    CrossRef] [Google Scholar] [Publisher Link]
  15. Ali Sophian et al., “A Feature Extraction Technique based on Principal Component Analysis for Pulsed Eddy Current NDT,” NDT and E International, vol. 36, no. 1, pp. 37-41, 2003.
    [
    CrossRef] [Google Scholar] [Publisher Link]
  16. Weiying Cheng, “Pulsed Eddy Current Testing of Carbon Steel Pipes’ Wall-Thinning through Insulation and Cladding,” Journal of Nondestructive Evaluation, vol. 31, no. 3, pp. 215-224, 2012.
    [
    CrossRef] [Google Scholar] [Publisher Link]
  17. Zhiyuan Xu et al., “Assessment of Wall Thinning in Insulated Ferromagnetic Pipes using the Time-to-Peak of Differential Pulsed Eddy-Current Testing Signals,” NDT and E International, vol. 51, pp. 24-29, 2012.
    [
    CrossRef] [Google Scholar] [Publisher Link]
  18. Nalika Ulapane et al., “Non-Destructive Evaluation of Ferromagnetic Material Thickness using Pulsed Eddy Current Sensor Detector Coil Voltage Decay Rate,” NDT and E International, vol. 100, pp. 108-114, 2018.
    [
    CrossRef] [Google Scholar] [Publisher Link]
  19. Nalika Ulapane, and Linh Nguyen, “Review of Pulsed-Eddy-Current Signal Feature-Extraction Methods for Conductive Ferromagnetic Material-Thickness Quantification,” Electronics, vol. 8, no. 5, pp. 1-13, 2019.
    [
    CrossRef] [Google Scholar] [Publisher Link]
  20. Sud Sudirman et al., “Pulsed Eddy Current Signal Processing using Wavelet Scattering and Gaussian Process Regression for Fast and Accurate Ferromagnetic Material Thickness Measurement,” Alexandria Engineering Journal, vol. 61, no. 12, pp.     11239-1125, 2022.
    [
    CrossRef] [Google Scholar] [Publisher Link]
  21. Wai Yie Leong, “AI-Driven Predictive Safety Analytics for Accident Prevention in Smart Manufacturing,” Intelligent Manufacturing and Cloud Computing: Proceedings of the 2nd International Conference, Wuhan, China, pp. 11-20, 2026.
    [CrossRef] [Google Scholar] [Publisher Link]