Mathematical Modelling For Rotating Biological Contactor for Treatment of Grey wastewater

International Journal of Civil Engineering
© 2019 by SSRG - IJCE Journal
Volume 6 Issue 5
Year of Publication : 2019
Authors : Dr.S. Syed Enayathali
pdf
How to Cite?

Dr.S. Syed Enayathali, "Mathematical Modelling For Rotating Biological Contactor for Treatment of Grey wastewater," SSRG International Journal of Civil Engineering, vol. 6,  no. 5, pp. 6-10, 2019. Crossref, https://doi.org/10.14445/23488352/IJCE-V6I5P102

Abstract:

The laboratory model of the two-stage Rotating Biological Contactor (RBC) used in the present study is a modified one, with a provision to vary the speed of rotating blades. Grey wastewater was used to study the performance of the modified rotating biological contactor. The reactor had four rotating blades in each stage, having 300 mm x100 mm x 10 mm, attached perpendicular to the shaft. The experiment was conducted for different influent COD loads and different speeds of rotating blades. Mathematical Models, Kornegay models, and Hudson models were used to evaluate the kinetic coefficients to describe RBC kinetics for treating greywater.

Keywords:

RBC; rotating blades; Greywater; COD; OLR.

References:

[1] Eriksson, E., Auffarth, K., Henze, M. and Ledin, A., Characteristics of Grey Wastewater, Urban Water, 4(1), (2002),85.
[2] Baban, A., Murat, H., Atasoy, E., Gunes, K., Ayaz, S., Regelsberger, M., Grey water Treatment and using RBC – a kinetic approach, In: Proceeding of the 11th International Conference on Environmental Sci. and Tech., Greece, (2009),48–55.
[3] Sheehan, G.J & Greenfield, P.F., Utilization, treatment and disposal of distillery wastewater, water res.,14, (1980),257-277.
[4] Ruiz, I., M.Soto, M.C.Veiga, P.Ligero, A.Vega, and R.Blazquez, Performance of and biomass characterization in UASB reactor treating domestic wastewater at ambient temperature. Water SA, 24(3),(1998),215-221.
[5] APHA, AWWA, WEF, Standard Methods for the Examination of Water and Wastewater, 18th Ed., Washington DC, USA.,(1998).
[6] Nolde, E., Greywater reuse systems for toilet flushing in multi-story buildings over ten years experience in Berlin, Urban Water 1,(1999),275–284.
[7] Judd, S., The MBR Book Principles and Applications of Membrane Bioreactors in Water and Wastewater Treatment, Elsevier, Oxford.
[8] P.Artiga, M. Carballa, J.M. Garrido and R.Mendez., Treatment of winery wastewaters in a membrane submerged bioreactor.
[9] Friedler, E., Kovalio, R, and Galil, N.I, On-Site Greywater Treatment and Reuse in Multi-Storey Buildings, Water Science Technology, 51(10),(2005),187-94.
[10] Nolde, E., Greywater Reuse Systems for Toilet Flushing in Multi-Storey Buildings, - Over Ten Years Experience in Berlin, UrbanWater.,1-4,(2000),275-284.