Design and Analysis of High-Rise Building using STAAD Pro

International Journal of Civil Engineering
© 2019 by SSRG - IJCE Journal
Volume 6 Issue 6
Year of Publication : 2019
Authors : T. Dinesh Kumar, Mohammed Ibrahim, Mohammed Ismail Pasha Quadri, Mohammed Sohail Ali, Syed Abdul Rahman, Mohammed Akbar Khan
pdf
How to Cite?

T. Dinesh Kumar, Mohammed Ibrahim, Mohammed Ismail Pasha Quadri, Mohammed Sohail Ali, Syed Abdul Rahman, Mohammed Akbar Khan, "Design and Analysis of High-Rise Building using STAAD Pro," SSRG International Journal of Civil Engineering, vol. 6,  no. 6, pp. 7-14, 2019. Crossref, https://doi.org/10.14445/23488352/IJCE-V6I6P102

Abstract:

This project's principle objective is to analyze and design a multi-story building [G + 10 (3-dimensional frame)] using STAAD Pro. The Design involves load calculations and analyzing the whole structure by STAAD Pro. The design methods used in STAAD-Pro analysis are Limit State Design conforming to Indian Standard Code of Practice. STAAD. Pro features a state-of-the-art user interface, visualization tools, powerful analysis, and design engines with advanced finite element and dynamic analysis capabilities. From model generation, analysis, and Design to visualization and result verification. The loads considered for designing the residential building are Gravity Load, which includes dead loads and live loads, and Lateral load, including only Wind Loads. The total height of a building is 30m, and the area of a residential building is around 9,048 sq. ft.

Keywords:

STAAD Pro, Limit State Design, Gravity Load, Lateral Load, High-Rise Building, Design, Analysis.

References:

[1] IS 875 (Part 1) – 1987 for Dead Loads, Indian Standard Code Of Practice for Design Loads (Other Than Earthquake) For Buildings and Structures, Bureau of Indian Standards, Manak Bhavan, 9 Bahadur Shah Zafar Marg, New Delhi 1100 02.
[2] IS 875 (Part 2) – 1987 for Imposed Loads, Indian Standard Code Of Practice for Design Loads (Other Than Earthquake) For Buildings and Structures, Bureau of Indian Standards, Manak Bhavan, 9 Bahadur Shah Zafar Marg, New Delhi 110002.
[3] IS 875 (Part 3) – 1987 for Wind Loads, Indian Standard Code Of Practice for Design Loads (Other Than Earthquake) For Buildings And Structures, Bureau of Indian Standards, Manak Bhavan, 9 Bahadur Shah Zafar Marg, New Delhi 110002.
[4] IS 875 (Part 5) – 1987 for Special Loads and Combinations, Indian Standard Code Of Practice for Design Loads (Other Than Earthquake) For Buildings and Structures, Bureau of Indian Standards, Manak Bhavan, 9 Bahadur Shah Zafar Marg, New Delhi 110002.
[5] IS 456-2000, Indian standard code of practice for plain and reinforced concrete standards, New Delhi, 1980.
[6] SP: 34-1987, Hand Book of Concrete Reinforcement and Detailing, Bureau of Indian Standards, New Delhi, 1987.
[7] K. Sai Vivek, K. Siva Kiran, Design Aid for Unstiffened Triangular Steel Brackets based on Elastic Stability, SSRG International Journal of Civil Engineering 3(12) (2016) 7-16.
[8] Pilli, S.U. And Menon .D, ―” Reinforced concrete design,” Second edition, Tata McGraw Hill Publishing Company Limited, New Delhi, 2003.
[9] Jain, A.K. ―Reinforced Concrete – “Limit State Design,” Sixth Edition, New Chand & Bros, Roorkee, 2002.